Sunday, May 24, 2020
Classification Phase Of Induction Generator - 894 Words
NOMENCLATURE d-q stator voltages of induction generator d-q stator currents of induction generator d-q rotor currents of induction generator , stator and rotor resistances per phase of induction generator stator, rotor and magnetizing inductances of induction generator self excitation capacitance per phase of induction generator Angular stator frequency of the induction generator Angular rotor speed (electrical rads/s) of the induction generator moment of inertia friction coefficient, differential operator d/dt DC-link inductance DC-link resistance firing angles of the converter and inverter d-q input voltage of the converter d-q input current of the converter DC-link current inverter output voltage d-q stator voltages of synchronous generator d-q damper winding voltages of synchronous generator field winding voltage of synchronous generator d-q stator currents of synchronous generator d-q damper winding currents of synchronous generator field winding current of synchronous generator st ator resistance of synchronous generator d and q damper winding resistances d and q mutual inductances d and q self inductances rotor speed (electrical rads/s) of the synchronous generator torque input from diesel engine applied and actual fuel flow rate of diesel engine combustion delay time constant time constant and gain of fuel rack position actuator prediction horizon.Show MoreRelatedRenewable Resources Wind Energy Is An Important Factor For The New Era Of Power Quality1568 Words à |à 7 Pageswind diesel system is considered in this project. Recent technology, ââ¬Å"permanent magnet typeâ⬠have advantages and disadvantages. They are also discussed here. To convert the energy generated by wind generation, induction generator as it have many advantage over the other types of generators. Connection with the strong grids during the wind energy conversion poses less power quality problems compared to weak grids or isolated. The best solution for serving the mini-grids and isolated loads in remoteRead MoreA High-Performance Control Model Of Grid-Connected Wind1014 Words à |à 5 Pagesregulate the sustainable power system to the grid. Phase locked loop is used (PLL) is applied to manage the synchronisation of the network [6]. Achieve the method to obtain the greatest output of mechanical power which can be produced from wind turbines at specific wind rate and integrate the produced energy to the utility is a challenging area. A permanent magnet synchronous generator is a used generator, which is also a changeable speed generator. Also, the pitch angle controller is used to allowRead MoreWavelet Based Protection Scheme For Multi Terminal Transmission System2124 Words à |à 9 Pagesnew approach for detection, discrimination of the faults for multi terminal transmission line protection in presence of hybrid generation. Transient current based protection scheme is developed with discrete wavelet transform. Fault indices of all phase currents at all terminals are obtained by analyzing the detail coefficients of current signals using bior 1.5 mother wavelet. This scheme is tested for different types of faults and is found effective for detection and discrimination of fault withRead MoreTypes of Dc Motors and Dc Generator2262 Words à |à 10 PagesTypes of DC Motors and DC Generators MOTORS ââ¬â convert electrical energy to mechanical energy Motors and generators are the most frequent used electrical machines. â â" Generators action can take place when and only when, there is a relative motion between conducting wires and magnetic lines of force. â â" Electric motor is in operation when it is supplied with electrical energy and develops torque, that is, a tendency to produce rotation. â â" In DC generator, the armature winding is mechanicallyRead MoreStudy Of Transient Stability For Ieee 14 Bus Power System4537 Words à |à 19 Pagesbus system studied. Transient stability under three phase fault is investigated via simulation using PSAT on a MATLAB platform. Some part of the conventional generation of the standard system is replaced with DFIG based wind power generation and the system is analyzed for fault at different locations. Study shows that the system becomes vulnerable to instability with the addition of wind power generation. Keywordsââ¬âDouble fed Induction Generator (DFIG), Wind Turbine, Vector Control, d-q axis. I.Read MoreJntuk 2-1 and 2-2 Mech Syllabus R105047 Words à |à 21 PagesThermodynamic Potentials, Gibbs and Helmholtz Functions, Maxwell Relations ââ¬â Elementary Treatment of the Third Law of Thermodynamics. UNIT IV Pure Substances, p-V-T- surfaces, T-S and h-s diagrams, Mollier Charts, Phase Transformations ââ¬â Triple point at critical state properties during change of phase, Dryness Fraction ââ¬â Clausius ââ¬â Clapeyron Equation Property tables. Mollier charts ââ¬â Various Thermodynamic processes and energy Transfer ââ¬â Steam Calorimetry. UNIT - V Perfect Gas Laws ââ¬â Equation of State, specificRead MoreComparative Study Of Different Pwm Strategies2649 Words à |à 11 PagesComparative study of different PWM Strategies for Three Phase three-level Diode Clamped Multi-level Inverter M. Satyanarayana Research Assistant Department of Electrical Engineering University College of Engineering Osmania University Hyderabad, Telangana, INDIA D. Naveen Kumar Associate Professor Department of Electrical and Electronics Engineering Guru Nanak Institutions Technical campus Hyderabad, Telangana, INDIA Abstractââ¬â This paper presents unipolar pulse width modulation techniqueRead MoreBoon and Bane of Nuclear Power3477 Words à |à 14 Pagesbe ready? Are we aware of what it will cost us? Nuclear Power Plants A nuclear power plant, like any other power plant, is a facility used to provide electricity. However, it uses a nuclear reactor as heat source to provide steam to a turbine generator. These plants depend on the heat caused by controlled nuclear reactions, specifically nuclear fission, where one atom is made to split into two. There is a need for such kind of power plants to be housed in very strong steel and concrete to preventRead MoreThe Power Grid Corporation Of India Limited Essay6778 Words à |à 28 Pagesbased Thermal Power Station. A coal based thermal power plant converts the chemical energy of the coal into electrical energy. This is achieved by raising the steam in the boilers, expanding it through the turbine and coupling the turbines to the generators which converts mechanical energy into electrical energy. The design of a power plant should incorporate two important aspects. Firstly, the selection and placing of necessary power generating equipment should be such so that a maximum of returnRead MoreWbut Syllabus 1st Sem11442 Words à |à 46 PagesExpression for change in internal energy for ideal gas. Enthalpy: Definition, Characteristics, Physical significance, Mathematical expression for change in Enthalpy, Expression for change in enthalpy for ideal gas. 3L Heat Capacity: Definition, Classification of Heat Capacity (Cp and CV): Definition and General expression of Cp - CV. Expression of Cp - CV for ideal gas. Reversible and Irreversible processes: Definition, Work done in Isothermal Reversible and Isothermal Irreversible process for Ideal
Subscribe to:
Post Comments (Atom)
No comments:
Post a Comment
Note: Only a member of this blog may post a comment.